Reolink Doorbell Wired Full Offset Brick Extension Mount | Max Clearance
Compatibility: Reolink Doorbell (Wired Only) & Trim Width
- Fits ONLY: The **Reolink Video Doorbell Wired** (PoE or Wi-Fi versions that share the same physical body).
- Confirm your model matches the picture below:
-
(Example Image - Click for Amazon Link. As an Amazon Associate, I earn from qualifying purchases.) - WILL NOT FIT: The Reolink Video Doorbell WiFi (Battery version) or doorbells from other brands.
- Surface Width: Requires mounting surface (trim/molding) to be AT LEAST 9/16 inches wide for the base.
Please double-check your Reolink model before ordering!
Maximum Door Clearance for Your Reolink Wired Doorbell!
Is your Reolink Wired Doorbell mounted on trim recessed behind brick? Need maximum clearance from a close door swing or storm door? This **Full Offset Brick Extension Mount** is the ideal solution for these tight installations!
It extends your Reolink doorbell forward past the brick face (select the length needed) and uses our **Full Offset** design to shift the doorbell body entirely sideways over the brick, maximizing space next to your door. Installs on narrow trim (>= 9/16" wide) without drilling into your masonry.
How it Works: Full Offset (Maximum Sideways Shift)
This mount utilizes our unique FULL OFFSET geometry. Your Reolink Wired Doorbell attaches so its door-facing edge aligns flush with the side edge of the narrow 9/16" mount base. This provides the maximum possible horizontal shift over adjacent brick compared to our Standard Offset mounts.
This is the best choice when door swing clearance is the primary concern. The offset is reversible for left or right side mounting.
This mount positions the doorbell over or in front of the brick face.
Full Offset (This Product) vs Standard Offset:
Need standard (less) offset? Click here for the Standard Offset version for the Reolink Wired Doorbell.Base Dimensions & Mounting: The extension base is 9/16 inches wide (requires >= 9/16" surface). Standard mounting hole spacing is 2.5 inches (center-to-center). Ensure solid mounting on trim. Wall-mounting screws not included.
Angled Trim? If your trim is angled, add our Angle Shims (sold separately) for a perpendicular installation.
CRITICAL: Measure & Select Your Extension Length!
Choose the correct length to clear your brickwork or storm door. Measure carefully:
- Measure the exact distance straight out from the surface where the mount base will attach (your trim) to the outermost face of your brick or obstacle.
- Order THIS measurement as your required Extension Length. (Do NOT subtract doorbell thickness for offset mounts).
Select the required extension length from the dropdown menu when ordering. (Starts at 1/4 inch).
Need help measuring? Text/email a picture! (Contact info below)
Measure like this from Trim to Brick Face for Extension Length.
Key Features & Benefits:
- Maximum Sideways Offset: Full Offset design for ultimate door swing clearance.
- Designed for Reolink Wired Doorbell: Ensures compatibility with the Reolink Wired (PoE/WiFi) model.
- "Over Brick" Placement: Extends doorbell forward past brick and positions it fully over the brick face.
- Avoid Drilling Brick: Mounts to existing trim (>=9/16" wide, Std. 2.5" hole spacing).
- Selectable Extension Length: Order the precise depth needed (Trim-to-Brick/Obstacle measurement).
- Narrow Base (9/16" Std): Designed for tight trim installations.
- Wire Passthrough: Internal channel accommodates wiring.
- Reversible Offset: Base can be flipped for left or right offset.
- Durable PETG Construction: Strong, weather-resistant plastic.
- Add-on Compatible: Works with angle shims, fillers etc. (see below).
- Future-Proof Bracket: Top adapter bracket potentially replaceable for future upgrades (check compatibility).
How to Install Your Full Offset Extension for Reolink Wired
This mount uses two main printed pieces: the Extension Base and the Doorbell Adapter Bracket.
-
Tools & Prep: Gather: Drill, PH1 & PH2 Philips Screwdrivers/Bits, Level, Anchors (if needed), Reolink mounting bracket/wedge & screws.
Turn OFF power at the breaker AND disconnect Ethernet cable if using PoE!
-
Mount Extension Base: Position the Extension Base (correct length/offset) on trim over wires (ensure Full Offset provides max clearance needed). Attach securely using appropriate screws (#6 size likely, use PH2) and anchors into the 2.5" spaced holes.
Ensure base is level. Don't overtighten.
-
Attach Doorbell Adapter Bracket: Route wires through the Doorbell Adapter Bracket (top piece for Reolink). Align onto Extension Base. Attach using the four small center screws provided (likely #4 screws / PH1 driver).
Use correct PH1 bit. Tighten until flush. Check for/clear debris if needed. Do NOT over-torque.
-
Attach Reolink Backplate: Secure the **backplate/wedge that came WITH your Reolink Doorbell** onto the Doorbell Adapter Bracket using the small screws PROVIDED WITH THIS MOUNT (typically #4 / PH1). Ensure correct orientation.
Do NOT use Reolink's long wall screws here. Use correct PH1 driver.
- Wire & Mount Reolink Doorbell: Connect wires (Power and/or Ethernet) to the Reolink backplate/wedge according to Reolink's instructions. Mount the Reolink Doorbell unit onto its backplate/wedge.
- Final Check & Power On: Ensure doorbell is secure. Turn power back on and test.
Follow safety rules & Reolink guidelines. Use correct anchors/screws. Correct screwdriver size prevents stripping.
Optimize Your Reolink Doorbell Placement
Optimal Positioning for Enhanced Security
The Reolink Doorbell Full Offset Brick Extension allows you to install your doorbell in a location that maximizes its capabilities, especially when facing recessed trim and tight clearances. The full offset ensures your doorbell camera captures clear video footage without obstruction.
Easy Installation on Trim
Installing your Reolink doorbell with this mount onto existing trim is straightforward. It’s designed to avoid drilling into brick, and detailed instructions simplify the DIY installation process.
Durable Construction for Long-lasting Use
Built from high-quality PETG, the Reolink brick extension is designed to resist wear and tear from the elements, ensuring your doorbell remains securely attached and functional year-round.
Optional Add-ons & Accessories:
Further customize your installation:
-
Angle Shims (5°, 10°, 15°)
Corrects for angled trim *under the Extension Base*.
-
Horizontal Angle Adapter or Swivel Add-on
Add horizontal angle adjustment to the end of the extension.
-
Bottom Filler Spacer Plate
Fills the gap below the extension base on angled/uneven trim.
-
Body Shim Filler Plate
Fills gaps between the extension body and uneven brick.
-
Add Side Wire Entry
Adds side entry holes ("mouse holes") to the *Extension Base* (add service to cart).
-
Wire Extension Kit
Need longer wires? Purchase our extension wire kit with your choice of connectors.
Product Examples
(See listing photos for details or contact us for more examples!)
Need Help? Confirm Compatibility & Measurements!
Ensure you have the Reolink Wired Doorbell (PoE or WiFi). Need help measuring extension length or choosing Full vs Standard Offset?
- Email: shop@doorbellmount.com (Send Pictures!)
- Text/Call: 1-833-326-6868 (Text Pictures!)
Standard Color: Black. For other colors, add the Color Change Request item.
Doorbell Not Included. Includes the 2-piece extension mount (Extension Base + Doorbell Adapter Bracket) and necessary assembly screws.
PETG Material: Printed in durable, outdoor-rated PETG.
3D Printed Quality: Minor cosmetic variations inherent to 3D printing may exist but do not affect function. Contact us with quality concerns before reviewing.
Order the Full Offset Brick Extension for maximum clearance with your Reolink Wired Doorbell! Remember to measure carefully (Trim to Brick Face!) and select your required extension length.